About Us

WORKING PRINCIPLE

OXFTM Series Thermal Mass Flowmeter measures the gas mass flow base on thermal diffusion theory. It has two filmed RTDs as its sensors, one of which sense the velocity of the gas flow (RH) and the other one will detect the temperature shift of the gas flow (RMG). When the two RTD are in the gas flow ,the RH will be heated while the RMG will sense the temperature changing of the gas flow. More heat will be taken away as the velocity of the gas flow increasing, so the temperature on RH will decline.

SPECIAL FEATURES

  • Direct mass flow or normalized flow measurement
  • 100:1 turn down ratio in 5 ranges: 0.3-30Nm/s, 0.6Nm/s-60 Nm/s,
  • 9-90Nm/s, 1.2-120Nm/s, or 1.5–lS0Nm/s
  • No pressure loss, suitable for pipe in any shape with known sectional area
  • For the insertion type, installation and maintenance can be performed while in service
  • High accuracy data acquisition circuit to ensure outstanding repeat­ ability and accuracy
  • Real time Natural Gas composition mixture (C4-C6) input via Modbus for higher accuracy measurements
  • High efficiency design of power supply, the total power consumption is only 60mA@24VDC
  • 16V-32V wide voltage range input
  • Self-diagnose function plus remote diagnose function, ensure easier trouble-shooting and meter verification for accuracy and reliability
  • Ex-proof version optional
  • Bluetooth communication for reading, setting and diagnosis through Smart Device APP
  • No moving parts
ParameterSpecification
Flow Range0.25 to 150 SFPS (Standard Feet Per Second)
Accuracy±1% of reading ±0.5% of full scale
Repeatability±0.2% of full scale
Turn-down RatioUp to 100:1
Operating Temperature-40°C to +100°C
Pressure RatingUp to 300 psig (standard), higher options available
Power Supply24 VDC or loop-powered
Output Signal4–20 mA, HART, Modbus RTU
EnclosureNEMA 4X/IP66
Sensor Material316L Stainless Steel
MountingInline or insertion type
DisplayOptional local display with keypad
ProbeHL
11.42″ (290 mm)17.07″10.06″
17.32″ (440 mm)22.97″15.97″
27.12″ (690 mm)32.82″25.81″
39.37″ (1000 mm)45.02″38.01″
59.06″ (1500 mm)64.71″57.70″

 

MAX PIPE SIZE THAT EACH PROBE CAN ADAPT TO
Probe length290mm440mm690mm1000mm1500mm
< 50 dgr CDN150DN450DN900DN1500DN2500
50 °C < T < 150 °CIDNl00DN600DN1200DN2200
150 °C < < 250 °CIIDN400DNl000DN2000
250 °C < T < 450 °CIIDN300DN600DNl000
T < 122 °F6″18″36″60″100″
122 °F < T < 302 °FI4″24″48″88″
302 °F < T < 482 °FII16″40″80″
482 °F < T < 842 °FII12″24″40″

 

OTHER PROCESS CONNECTION

Flanged insertion type

For applications with pressure higher than 230 psig (1.6MPa)

Flanged type

For in-line connection, 230 psig- 914 psig (1.6 - 6.3 MPa) and different flanged standard available

STANDARD VOLUME FLOW RATE RANGE IN POPULAR SIZES

Pipe size
(mm)
Pipe size
(inch)
Option 1 (0.3-30 Nm/s)Standard (0.6-60 Nm/s)Option 2 (0.9-90 Nm/s)Option 3 (1.2-120 Nm/s)
Min flow
Nm³/hr
Max flow
Nm³/hr
Min flow
Nm³/hr
Max flow
Nm³/hr
Min flow
Nm³/hr
Max flow
Nm³/hr
Min flow
Nm³/hr
Max flow
Nm³/hr
251″0.53531.05105.91.58158.82.11211.8
321¼”0.8786.71.73173.52.6260.33.47347.1
401½”1.36135.62.71271.14.06406.75.42542.3
502″2.12211.94.23423.76.35635.58.47847.4
652½”3.58358.17.1716.110.71074.114.31432.2
803″5.42542.310.81084.716.21627.121.62169.4
1004″8.47847.516.91694.925.42542.333.83389.8
1255″13.21324.226.42648.339.73972.452.95296.6
1506″19.11906.838.13813.557.25720.376.27627.1
2008″33.93389.867.76779.6101.610169.4135.513559.3
25010″535296.6105.910593.2158.815889.8211.821186.4
30012″76.37627.1152.515254.2228.822881.330530508.4

 

Mode number

The standard model number is usually OXFTM-1-2-12-1-N-T-M-N-1-1-XXXX, 
Please reference to the table below for what the model codes stand for.

SectionCodeDescriptionType
General modelOXFTM Standard
  Air/nitrogenStandard
2 Fluid type2Oxygen (sensor will be degreased)Option
 3Other (Please advise gas composition)Option
  0.3-30 Nm/sOption
 20.6-60 Nm/sStandard
3 Measurement30.9-90 Nm/sOption
range41.2-120 Nm/sOption
 51.5-150 Nm/sOption
 61.8-180 Nm/sOption
 11Insertion type with 290mm probeOption
 12Insertion type with 440mm probeStandard
 13Insertion type with 690mm probeOption
 14Insertion type with 1000mm probeOption
 15Insertion type with 1500mm probeOption
 FlFlanged insertion type up to 25 barG (362 psiG)Option
 F2Flanged insertion type up to 40 barG (580 psiG)Option
 F2Flanged insertion type up to 63 barG (913 psiG)Option
4 ProcessDlFlanged DIN PN16 up to 16 barG (232 psiG) (DN15-DN300)Option
connectionD2Flanged DIN PN25 up to 25 barG (362 psiG) (DN15-DN300)Option
 D3Flanged DIN PN40 up to 40 barG (580 psiG) (DN15-DN300)Option
 D4Flanged DIN PN63 up to 63 barG (913 psiG) (DN15-DN300)Option
 ClFlanged ANSI CL150 up to 16 barG (232 psiG) (0.5 inch–12 inch)Option
 C2Flanged ANSI CL300 up to 40 barG (580 psiG) (0.5 inch–12 inch)Option
 C3Flanged ANSI CL400 up to 63 barG (913 psiG) (0.5 inch–12 inch)Option
 JlJIS 10K up to 16 barG (232 psiG) (DN15–DN300)Option
 J2JIS 20K up to 40 barG (580 psiG) (DN15–DN300)Option
 J3JIS 30K up to 63 barG (913 psiG) (DN15–DN300)Option
5 Wetted part 316ss sensor with 304ss wetted partsStandard
material2316ss sensor with 316ss wetted partsOption
Medium tempN< 150°CStandard
6 rangeQ< 250°COption
 H< 450°C (please select remote display also)Option
7 TransmitterTIntegralStandard
 RRemoteOption
8 Cable grinderMM20 x 1.5Standard
 NNPT 1/2Option
9 Ex-proofNNo Ex-proofStandard
  NEPSI Ex d IIC T3 GbOption
  pulse/frequency + 4-20mA + RS485 + BluetoothStandard
 2pulse/frequency + 4-20mA @ HART + BluetoothOption
11 Power supply 13.5–42VDCStandard
 213.5–42VDC with 85–265VAC 50/60Hz power converterOption
12 Pipe sizexxxxPlease use 4-digit pipe size, such as DN50=0050, DN300=0300xxxx